5.8 Frame status (LEDs)
PSU status is presented in the following ways:
Symbol
Green LED
Yellow LED
Red LED
No LED
PSU module
none
Power is OK
Voltage or
current alarm
Power
off
Frame front
Power is OK
Communication
problem with
fan front*
Voltage or
current alarm
Power
off**
Temperature
/fans are OK
Communication
problem with
fan front*
Temperature
/fans alarm
Power
off**
* Lack of communication with PSU in non-RP mode or one of the PSU’s in RP mode.
(In both situations the fans will have permanent maximum speed)
** PSU in non-RP mode or both of the PSU’s in RP mode
5.8.1 Multicon
- Multicon GUI which presents the following information
o Measured voltages
o Measured currents at each frame voltage
o Total provided power
o Internal PSU temperature
o Alarm status for;
voltages
currents
total provided power
temperature
Defect fan
Figure 28: Example of PSU interface in Multicon
- GPI
o See description in chapter “GPI Power Supply Status outputs”.